Designation | TS3004 | TS3007 |
---|---|---|
Design code | PED 2014/68/EU | PED 2014/68/EU |
Integrated cooling coil | ■ | ■ |
Volume, vessel (liters) | 3.5 | 6.7 |
Volume, tube (liters) | 0.2 | 0.5 |
Allowable pressure1) | 8 bar (116 PSI) |
8 bar (116 PSI) |
Allowable temperature1) | -10 °C ... +140 °C (14 °F … + 284 °F) |
-10 °C ... +140 °C (14 °F … + 284 °F) |
Cooling capacity – natural circulation (kW)2) | 1 | 2 |
Cooling capacity – forced circulation (kW)2) | 2 | 4 |
Metal parts | 1.4571 | 1.4571 |
Seal | EPDM | EPDM |